Skip to main content
Follow us on: 
PLATES & GASKETS

Gasket Selection.

Provide the following information to our THS sales team for a quote at Contact THS SERVICE or 905-831-4963.

  • 1.
    Manufacturer
  • 2.
  • 3.
    Application (Water, Steam, Glycol)
  • 5.
  • 6.
    Quantity
  • 7.
    Type
  • 8.
    Nameplate Image

Model Finder

  1. Measure the center to center mm of the port holes horizontal (A) and vertical (B).

  2. Choose Manufacturer for model chart 

Hisaka Gaskets

Hisaka Gaskets

Model UX 005 UX 01 UX 10
UX 11 / 22
UX 20
UX 21 / 22
UX 30
UX 31 / 32
UX 40
UX 41 / 42
A = mm 160 300 390 550 610 760
B = mm 331 850 1080 1540 1891.5 2135
             
Model UX 80 UX 90
UX 91 / 92
UX 100
102-103-104
EX 11 EX 15 SX 40
SX 43 / 45
A = mm   1300 1570 760 550 805
B = mm   2829 3590 + 2100 1445 2165
             
Model SX 41/ 44 SX 70
SX 71 / 74
RX 00
RX 01 / 02
RX 10
RX 13 / 14
RX 30
RX 31 / 32
RX 70
RX 71 / 72
A = mm 805 1070 242 450 650 985
B = mm 2165 2692 488 1080 1850 2490 +
             
Model LX 00
LX 01 / 02
LX 10
LX 11 / 12
LX 20
LX 21 / 22
LX 30
LX 31 / 32
LX 40
LX 41 / 42
LX 50
LX 51 / 52
A = mm 350 460 580 650 790 810
B = mm 787 1066 1593 1575-1675 2075 1995

Material

Selecting the wrong gasket can be a timely and costly mistake. Let our experienced THS sales team recommend the most durable and cost effective gasket material for your application by providing us with the pressure, temperature and process liquid details.

Buna (NBR/Nitrile), EPDM or Viton materials are the most common plate & frame heat exchanger gaskets depending on the operating application.

Food Grade
Standard Grade
Aggressive Chemical Compounds

Changes in Gaskets:

  • Time – Relaxes
  • Temperature – Deteriorates
  • Oxidizing Agents – Hardens
  • Swelling – Chemical Absorption

Gaskets Material Depends on:

  • Fluids Used
  • Temperature and Pressure

Standard Gasket Styles

Clip - will usually have rubber tabs that are visible from the outside of the heat exchanger

Glue – no tabs and in most cases the brown glue is visible under the gasket; typically used in high pressure or high temperature applications

Ball - used in HVAC or FDA applications to allow for easy removal in the field 

WHEN SHOULD A PLATE & FRAME HEAT EXCHANGER BE SERVICED?

As a heat exchanger becomes fouled with dirt, debris or scale, often the modulating valve provides additional hot or cold liquid to help compensate for the loss of efficiency of the heat exchanger.

Over time the control valve will continue to open fully. Unfortunately, on the hottest or coldest days, even with the valve fully open the heat exchanger cannot meet the thermal transfer requirements and the situation becomes critical.

Monitoring just the operating temperature provides a false sense of security. Recording the difference in the outlet and inlet pressures provides a more accurate result of the amount of fouling.

Fouling equal to the thickness of a piece of paper represents a 20% loss of thermal efficiency. In addition, the energy cost for pumps increases since the pump must work harder to overcome the increased pressure resistance through the PHE

Can Double Wall HXs Be Cleaned Using High Pressure Water?

Double wall plate and frame heat exchangers (HXs) are designed to prevent cross-contamination, making them critical for applications like potable water, food processing, and pharmaceuticals.

A common question is: Can double wall HXs be cleaned using high pressure water?

Yes, high-pressure water jetting is an effective method for cleaning double wall HXs, particularly for stubborn fouling. However, it requires careful execution to avoid damaging delicate components.

What Are Double Wall HXs?

Double wall HXs feature two plates between fluid channels, ensuring no mixing of fluids if a plate fails, as noted by T.H. Industrial Solutions. This design is vital for potable water systems under municipal codes, making regular cleaning essential to maintain performance and safety.

How Are Double Wall HXs Cleaned with High Pressure Water?

High-pressure water jetting, often at pressures up to 2,500 bar (36,000 psi), removes tough deposits like scale, marine growth, or debris from HX plates. The process typically involves:

  • Disassembly: Plates are separated to allow precise jetting, as high-pressure cleaning often requires manual application
  • Jetting: A 10 hp gas pressure washer, used by Heat Exchanger Ontario, effectively removes dirt and biofilm, though it may be less effective for scale or rust.
  • Inspection: Post-cleaning, dye penetrant testing checks for cracks or pinholes, ensuring plate integrity, a practice emphasized by T.H. Industrial Solutions.
  • Reassembly: Plates and gaskets are reinstalled carefully to maintain the double wall’s protective barrier.

Effectiveness of High-Pressure Water Cleaning

High-pressure water cleaning is effective for double wall HXs because it:

  • Clears Stubborn Fouling: Removes hardened scale and marine growth, restoring heat transfer efficiency
  • Targets Complex Geometries: Penetrates corrugated plate designs for thorough cleaning.
  • Reduces Chemical Use: Minimizes reliance on chemicals, eco-friendly when wastewater is managed

Limitations and Considerations

  • Risk of Damage: Excessive pressure can harm plates or gaskets, especially in stainless steel or titanium HXs
  • Time-Intensive: Disassembly and cleaning can take 2–3 days, compared to faster Clean-in-Place (CIP) methods
  • Wastewater Management: Generates significant wastewater, requiring proper treatment
  • Professional Expertise: Services from Total Heat Exchanger Solutions, ensure safe cleaning.

When to Use High-Pressure Water Cleaning

High-pressure water cleaning is ideal for double wall HXs with severe fouling, such as marine growth or hardened scale, where CIP or chemical flushing is insufficient. It’s common in industries like power generation or marine applications. For routine maintenance, CIP is often preferred to avoid disassembly.

Conclusion

Double wall HXs can be effectively cleaned with high-pressure water, particularly for tough deposits, but careful execution is needed to protect their anti-contamination design. Industry leaders like T.H. Industrial Solutions offer expert services to ensure efficiency and safety. Trust professionals to maintain your double wall HXs.

Can Double Wall PHEs Be Chemically Cleaned?

Double wall plate and frame heat exchangers (PHEs) are designed to prevent cross-contamination, making them essential for applications like potable water, food processing, and pharmaceuticals.

A common question is: Can double wall PHEs be chemically cleaned?

Yes, double wall PHEs can be effectively cleaned using chemical flushing or Clean-in-Place (CIP) methods, as confirmed by industry leaders like Heat Exchanger Ontario, ensuring efficiency and safety when performed by professionals.

What Are Double Wall PHEs?

Double wall PHEs feature two plates between fluid channels, providing a failsafe against leaks and cross-contamination, as noted by T.H. Industrial Solutions. This design ensures that if a plate develops a pinhole or crack, fluids remain separated, critical for potable water systems under municipal codes.

How Are Double Wall PHEs Chemically Cleaned?

Chemical cleaning methods for double wall PHEs include:

  • Clean-in-Place (CIP): Alfa Laval and Hofmann Heat Exchanger endorse CIP systems, which circulate non-toxic cleaning solutions like citric acid or Alfa P-Scale (sulphamic acid-based) to dissolve scale, for organic deposits like fats or biofilms, without disassembly.
  • Chemical Flushing: Heat Exchanger Ontario uses portable units with pumps and filters to circulate mild acid or citrus-based solutions for 6–8 hours, effectively removing debris, though less effective for hardened scale.
  • Post-Cleaning Rinse: After circulation, clean water flushes out residual chemicals and debris, followed by neutralization (e.g., using Alfa P-Neutra), ensuring environmental compliance.

Effectiveness of Chemical Cleaning

Chemical cleaning is highly effective for double wall PHEs because it:

  • Removes Fouling: Dissolves calcium carbonate, rust, and organic matter, restoring heat transfer efficiency and reducing pressure drops (7–10 psi indicates cleaning need), per T.H. Industrial Solutions.
  • Maintains Safety: Preserves the double wall’s protective barrier, critical for potable water
  • Minimizes Downtime: CIP cleaning, as offered by Hofmann Heat Exchanger, takes 6–8 hours without disassembly, ideal for food and pharmaceutical applications.

Limitations and Considerations

  • Hardened Scale: Severe fouling may require combining chemical cleaning with high-pressure water jetting
  • Material Compatibility: Chemicals must be compatible with plates (e.g., stainless steel) and gaskets to avoid corrosion
  • Environmental Compliance: Spent chemicals must be neutralized and disposed of per regulations
  • Professional Expertise: Services from T.H. Industrial Solutions ensure proper chemical selection and flow rates (e.g., 1 ft/sec).

When to Chemically Clean Double Wall PHEs

Chemical cleaning is recommended every 5–6 years or when differential pressure reaches 7–10 psi, indicating fouling. It’s ideal for routine maintenance in potable water or food systems, ensuring compliance with safety codes.

Conclusion

Double wall PHEs can be chemically cleaned using CIP or chemical flushing, effectively removing fouling while maintaining their anti-contamination design. Industry leaders like T.H. Industrial Solutions offer expert services to ensure efficiency and safety. 

T.H. Industrial Solutions Inc. (THS) has been servicing industrial plate and frame heat exchangers as with shell and tube heat exchangers.  Professionally solving process problems across Canada since 2009. THS head office is located in Pickering, Ontario with a 6,000 square foot service center in Hamilton, Ontario.

Today there are fewer qualified people in this industry that know the products and understand the applications. Utilizing hands on experience and knowledge that has been gained by our THS sales and service technicians for over the past 30 years, we will take the time to understand what you require and strive to provide a prompt, educated and accurate response at a competitive price.

Our Heat Exchanger Cleaning Services, along with heat exchanger gasket replacement systems, and knowledge of heat exchanger gasket materials make THS your Industrial Heat Exchanger Service Solution

THS Logo
HEAD OFFICE

1550 Bayly Street, Unit 15
Pickering, ON L1W 3W1

T 905 831-4963

SERVICE CENTER

76 Harlowe Road, Unit 4 - 7
Hamilton, ON L8W 3R6

T 905 318-0777
F 905-318-8422

Contact THS SERVICE


Proudly Canadian logo

©2024 T. H. Industrial Solutions Inc.  SITEMAP